[1]何那仁朝格图,邓国栋,鲁磊明,等.改性双基推进剂制备中硝化甘油的连续加料与计量技术[J].爆破器材,2017,46(04):59-64.[doi:10.3969/j.issn.1001-8352.2017.04.013]
 HE Narenchaogetu,DENG Guodong,LU Leiming,et al.Continuous Feeding and Measurement of Nitroglycerin in Preparation Process of Modified Double-base Propellant[J].EXPLOSIVE MATERIALS,2017,46(04):59-64.[doi:10.3969/j.issn.1001-8352.2017.04.013]
点击复制

改性双基推进剂制备中硝化甘油的连续加料与计量技术()
分享到:

《爆破器材》[ISSN:1001-8352/CN:32-1163/TJ]

卷:
46
期数:
2017年04
页码:
59-64
栏目:
安全与测试
出版日期:
2017-06-14

文章信息/Info

Title:
Continuous Feeding and Measurement of Nitroglycerin in Preparation Process of Modified Double-base Propellant
文章编号:
5160
作者:
何那仁朝格图邓国栋鲁磊明王路路王志强
南京理工大学国家特种超细粉体工程技术研究中心(江苏南京,210094)
Author(s):
HE Narenchaogetu DENG Guodong LU Leiming WANG Lulu WANG Zhiqiang
National Special Superfine Powder Engineering Center, Nanjing University of Science and Technology (Jiangsu Nanjing, 210094)
关键词:
硝化甘油乳化喷射器乳化混合质量流量计量
Keywords:
nitroglycerin (NG) emulsifying injector mixed emulsion mass flow measurement
分类号:
TQ560.7
DOI:
10.3969/j.issn.1001-8352.2017.04.013
文献标志码:
A
摘要:
为了实现改性双基推进剂制备过程中硝化甘油的安全输送和精确计量,利用乳化喷射器、直管质量流量计及数据处理器(PLC)对硝化甘油(NG)与水的混合液进行了连续加料与计量试验研究。利用Fluent模拟软件对NG的乳化喷液过程进行模拟分析,得到最佳的乳化喷射器结构参数为:喉管直径14.33 mm,喉管长度60.03 mm,喉嘴距12.00 mm;在此结构参数下进行模拟分析得到:乳化喷射器出口处NG最大体积分数小于30%,且所占节点比率小于0.05,说明NG与水混合均匀,确保了NG安全连续输送。研究了质量流量计在不同管道压力下对计量精度的影响,当管道压力为0.25~0.31 MPa时,能满足质量流量计的检测要求,计量误差≤1.0%,能满足改性双基推进剂连续制备的工艺要求。
Abstract:
In order to achieve the safe delivery and accurate measurement of nitroglycerin (NG) in the process of manufacturing modified double base propellant, three core innovations, emulsion ejector, straight tube mass flowmeter and PLC data processor, have been studied. The continuous addition and metering test on mixture of NG and water were carried out. Emulsification and spraying process of NG was simulated and analyzed by simulation software, FLUENT, from which the best structural parameters of the emulsifier were obtained: throat diameter is 14.33 mm, throat length is 60.03 mm, and distance between throat is 12.00 mm. Simulation analysis was performed under these structural parameters, and results show that the maximum volume fraction of NG at the exit of the emulsifying injector is less than 0.3 and the node ratio is less than 0.05, indicating that NG and water was mixed well to ensure the safety of continuous transmission of NG. Emulsifying injector, straight tube mass flow meter and PLC data processor were also applied in continuous addition and metering test of NG/water mixtures. Effects of mass flowmeter on the measurement accuracy under different pipelines pressures were identified. Pipeline pressure between 0.25 MPa and 0.31 MPa meets the requirements of mass flowmeter testing, and measurement error is no more than 1.0%, which meets the technical requirements of continuous preparation of modified double base propellant.

参考文献/References:

[1]张军. 火药组分在线连续计量及工艺研究[D]. 南京:南京理工大学,2012.
[2]朱陈森. 火药制备中NG的安全输送与计量技术研究[D]. 南京: 南京理工大学,2016.
 ZHU C S.Study on security transportation and measurement of NG[D]. Nanjing:Nanjing University of Science & Technology,2016.
[3]柴涛, 刘玉存, 吕林川. 硝化甘油生产系统的安全分析[J]. 中国安全科学学报,1998,8(4):38-42.
CHAI T,LIU Y C,Lǔ L C.Safety analysis in the process of nitro-glycerine production[J]. China Safety Science Journal,1998,8(4):38-42.
[4]吕飞, 刘宏英. 吸收药在线实时计量技术研究[J]. 新技术新工艺,2012(5):81-83.
 Lǔ F,LIU H Y.Study of on-line real time measurement technology of absorbent powder[J]. New Technology & New Process,2012(5):81-83.
[5]邓国栋,刘宏英,顾志明,等.硝化棉在线连续计量技术研究[J].爆破器材,2012,41(1):11-14.
DENG G D, LIU H Y, GU Z M, et al. Study on on-line continuous measurement technology of pure nitrocellulose weight[J].Explosive Materials,2012,41(1):11-14.
[6]骆培成, 程易, 汪展文, 等. 液-液快速混合设备研究进展[J]. 化工进展,2005,24(12):1319-1326.
LUO P C, CHENG Y, WANG Z W,et al. Research progress of liquid-liquid fast mixing equipment[J]. Chemical Industry and Engineering Progress,2005,24(12):1319-1326.
[7]张妍, 胡仰栋, 伍联营. 喷射混合器放大效应的计算流体力学模拟[J]. 化学反应工程与工艺,2013,29(6):495-501.
 ZHANG Y,HU Y D, WU L Y.Computational fluid dynamics simulation on the scale-up effect in ejectors[J].Chemical Reaction Engineering and Technology,2013,29(6):495-501.
[8]CRAMERS P H M R , BEENACKERS A A C M. Influence of the ejector configuration, scale and the gas density on the mass transfer characteristics of gas-liquid ejectors [J]. Chemical Engineering Journal,2001, 82(1/2/3):131-141.
[9]邓帆, 王国志, 于兰英,等. 液压油引射器的性能研究[J]. 机床与液压,2015,43(16):85-86,80.
DENG F,WANG G Z, YU L Y, et al. Performance research of the hydranlic oil ejector device[J]. Machine Tool & Hydraulics,2015,43(16):85-86,80.
[10]CHIN A, ELLISON D, POEHLEIN S, et al. Investigation of the decomposition mechanism and thermal stability of nitrocellulose/nitroglycerine based propellants by electron spin resonance [J].Propellants, Explosives, Pyrotechnics, 2007, 32(2):117-126.
[11]曹宝友. 质量流量计在石化行业的应用[J]. 石化技术,2015(9):41,45.
CAO B Y.Application of mass flow meter in petrochemical field[J]. Petrochemical Industry Technology,2015(9):41,45.
[12]泰皮. 含能材料[M]. 北京:国防工业出版社, 2009:198-201.
[13]左正金. 水的密度计算及应用[J]. 大坝观测与土工测试,1989(3):46-47 .
[14]王欢. 介质压力变化对质量流量计准确度的影响[J]. 石化技术,2014,21(4):40-42.
WANG H.Influence of medium pressure change on accuracy of mass flow meter[J]. Petrochemical Industry Technology,2014,21(4):40-42.

相似文献/References:

[1]刘晶①②,景青①②,陈松①②,等.硝化甘油喷射硝化器喷雾效果优化及试验验证[J].爆破器材,2016,45(05):1.[doi:10.3969/j.issn.1001-8352.2016.05.001]
 LIU Jing,JING Qing,CHEN Song,et al.Optimization and Experiment Verification of Nitration Spray Characteristic Used in Nitroglycerin[J].EXPLOSIVE MATERIALS,2016,45(04):1.[doi:10.3969/j.issn.1001-8352.2016.05.001]
[2]唐杰①,魏应东①,吴兴龙①,等.微反应系统合成硝化甘油的工艺研究[J].爆破器材,2020,49(05):36.[doi:10.3969/j.issn.1001-8352.2020.05.007]
 TANG Jie,WEI Yingdong,WU Xinglong,et al.Study on the Micro-chemical Synthesis Process of Nitroglycerin[J].EXPLOSIVE MATERIALS,2020,49(04):36.[doi:10.3969/j.issn.1001-8352.2020.05.007]

备注/Memo

备注/Memo:
收稿日期:2017-03-16
基金项目:国防火炸药科研专项项目(AS03141)
作者简介:何那仁朝格图(1993-),男,硕士研究生,从事材料工艺技术研究。E-mail:810036905@qq.com
通信作者:邓国栋(1965-),男,高级工程师,从事含能材料工艺技术研究。E-mail:13505196092@163.com
更新日期/Last Update: 2017-06-13