[1]袁长宏,袁玉红,谭玉明,等.电点火器输出p-t曲线出现负压的异常情况分析[J].爆破器材,2024,53(06):28-32,40.[doi:10.3969/j.issn.1001-8352.2024.06.005]
 YUAN Changhong,YUAN Yuhong,TAN Yuming,et al.Analysis of Abnormal Conditions of Negative Pressure in the Output p-t Curves of the Electric Igniter[J].EXPLOSIVE MATERIALS,2024,53(06):28-32,40.[doi:10.3969/j.issn.1001-8352.2024.06.005]
点击复制

电点火器输出p-t曲线出现负压的异常情况分析()
分享到:

《爆破器材》[ISSN:1001-8352/CN:32-1163/TJ]

卷:
53
期数:
2024年06
页码:
28-32,40
栏目:
爆炸材料
出版日期:
2024-12-06

文章信息/Info

Title:
Analysis of Abnormal Conditions of Negative Pressure in the Output p-t Curves of the Electric Igniter
文章编号:
5926
作者:
袁长宏袁玉红谭玉明曹平
安徽红星机电科技股份有限公司(安徽合肥,230011)
Author(s):
YUAN Changhong YUAN Yuhong TAN Yuming CAO Ping
Anhui Hongxing Electromechanical Technology Co., Ltd. (Anhui Hefei, 230011)
关键词:
电点火器p-t曲线负压
Keywords:
electric igniter p-t curve negative pressure
分类号:
TQ560.5
DOI:
10.3969/j.issn.1001-8352.2024.06.005
文献标志码:
A
摘要:
针对某型导弹发动机用电点火器在发火测试时出现的负压情况,进行了故障树分析排查、等效电路分析和试验验证,最终找到了该故障的原因是产品发火后绝缘性能失效,造成发火电路与测试电路耦合,形成电流回路,进而使电荷放大器输出端形成负压。对历次火工品发火测试时出现负压的情况进一步理论分析和试验验证表明,仅在使用压电式传感器的测试过程中出现负压,而应变式传感器则不会出现该故障。对分析电点火器类产品输出p-t曲线异常提供了参考。
Abstract:
Fault tree analysis, equivalent circuit analysis, and experimental verification were conducted to investigate the negative pressure situation that occurred during the ignition test of an electric igniter for a certain type of missile engine. Finally, the cause of the fault was found to be the insulation performance failure of the product after ignition, resulting in the coupling of the ignition circuit and the testing circuit to form a current loop, which in turn caused negative pressure at the output terminal of the charge amplifier. Further theoretical analysis and experimental verification were conducted on the occurrence of negative pressure during the ignition tests of various pyrotechnic devices. The results indicate that negative pressure only occurs during the testing process using piezoelectric sensors, while it does not occur when using strain gauges. It could provide a reference for analyzing the abnormal output p-t?curve of electric igniter products.

参考文献/References:

[1]姚良, 张世英, 华明军. 基于 p-t 曲线的导弹火工品品质测试 [J]. 宇航计测技术, 2004, 24(4): 14-16.
YAO L, ZHANG S Y, HUA M J. Quality testing of initiating explosive device in missiles based on p-t?curve [J]. Journal of Astronautic Metrology and Measurement, 2004, 24(4): 14-16.
[2]孙霖, 马爱武, 郭崇星, 等. 火工品作用后开路电阻的动态测量[J]. 火工品, 2007(1): 54-56.
SUN L, MA A W, GUO C X, et al. Dynamic measurement of shutdown resistance of initiating explosive device after function [J]. Initiators & Pyrotechnics, 2007(1): 54-56.
[3]宁心怡. 压电式加速度传感器电路原理[J]. 科技创新与应用, 2019(32): 42-45, 47.
[4]郝罗亮, 甘蓉, 汪帅, 等. 压电式压力传感器静态性能试验方法研究[J]. 计量与测试技术, 2023, 50(11): 46-50.
HAO L L, GAN R, WANG S, et al. Research on static performance test method for piezoelectric pressure sensors[J]. Metrology & Measurement Technique, 2023, 50(11): 46-50.
[5]廖湖广, 林伟国. 基于压电式压力传感器的压力容器气密性检测方法[J]. 北京化工大学学报(自然科学版), 2022, 49(5): 52-58.
LIAO H G, LIN W G. A pressure vessel air-tightness detection method based on a piezoelectric pressure sensor [J]. Journal of Beijing University of Chemical Technology (Natural Science), 2022, 49(5): 52-58.
[6]杨君琦. 应变传感器的应变传递理论及传感特性研究[D]. 长沙: 中南大学, 2013.
YANG J Q. Strain transfer theory and sensing property research of strain sensor [D]. Changsha: Central South University, 2013.
[7]左亚楠. 关于电阻应变式传感器灵敏度特性的分析[J]. 现代职业教育, 2018(17): 185.
[8]王凯民, 张学舜. 火工品工程设计与试验[M]. 北京: 国防工业出版社, 2014.
[9]郭晓荣, 刘晓莲, 吴瑞德, 等. 绝缘电阻故障对电火工品发火性能的影响[J]. 火工品, 2019(3): 10-13.
GUO X R, LIU X L, WU R D, et al. Influence of insulation resistance fault on firing property of electric explosive device [J]. Initiators & Pyrotechnics, 2019(3): 10-13.

备注/Memo

备注/Memo:
收稿日期:2024-01-12
第一作者:袁长宏(1972— ),男,高级工程师,主要从事军用火工品工程技术研究。E-mail:yuanch569@163.com
更新日期/Last Update: 2024-12-04